Datasheets
Description Type File Size
Download PDF 0.50mb
Quick Installation Guides
Version Description Date Type File Size
Download 4.00
WinXP, Vista 32, Vista 64, Win7 32, Win7 64
2/29/2012 - -

Providing Networking Solutions and Support

 
  • Premium Services is a Technical Consultation Service
  • We Offer Support on Most Internet and Networking Issues
  • Each Consultation up to 30 Minutes in Length with Three Subscription Plans to Choose From


Available Plans

Plan A

Plan B

Plan C

One Call

Three Calls

12 Months

$32.95

$64.95

$99.99
* Up to 12 calls



Support Staff:
The Premium Services staff have many years of experience in computer or computer related fields, with degrees, training and certifications in Engineering, A+, C+ CCNA, MCSE, and D-Link Technology.

Our technicians are trained to resolve most networking problems. If it is determined that the technician cannot solve the customers problem within the first few minutes the call may be escalated to a senior technician. In certain circumstances callbacks may be made to ensure customer satisfaction.

  • Premium Services is a Technical Consultation Service
  • We Offer Support on Most Internet and Networking Issues

Consumer:
Each Consultation up to 30 Minutes in Length with Three Subscription Plans to Choose From. Services are available from 6am-10pm PST / 7 days a week.

Disclaimer: Not all issues may be resolved over the phone.


Consumer Premium Services
Leading the Industry in Pay-For-Support Services!
Contact Us: 888-814-2882

Product Specifications

DPS-600

  • Redundant Power Supply Unit, 500 Watt RPSU

Input Voltage
  • 90VAC to 264VAC

Input Frequency
  • 47Hz to 63Hz

Input Current
  • 10A at 115VAC, 60Hz (maximum)
  • 5A at 230VAC, 50Hz (maximum)

Inrush Current
  • 30A at 115VAC, 60Hz input, 77°F (25°C) (maximum)
  • 60A at 230VAC, 50Hz, 77°F (25°C) (maximum)

Output Power
  • 500 watts (maximum)

Line Regulation
  • Less than + 2% (measuring at rated load and changing +/-10% of nominal input voltage)

Load Regulation (includes cross regulation between output voltages)
  • ±10% for +12V
  • ±3% for -50V

Hold Up Time

  • 16ms (typical) at 115VAC input and rated load from end of last charging pulse to when main output drops to 95% output voltage

Efficiency
  • 80% (typical) at nominal line and maximum load

Over Voltage Protection

  • Trip point: below 16V for + 12V output
  • Auto-recovery mode against short circuit or overload conditions
  • -50V output below -57V will protect itself against short circuit or overload conditions

Diagnostic LED
  • RPS good/failed

Physical & Environmental

MTBF

  • 598,664 Hours

Temperature
  • Operating: 32° to 122°F (0° to 50°C)
  • Storage: -40° to 185°F (-40° to 85°C)

Humidity
  • 10% ~ 90% RH, Non-condensing

Dimensions (Wx D x H)

  • 17.36 x 5.47 x 1.75in (441 x 139 x 44.5mm) 19-inch rackmount width, 1U height

EMI Approvals

  • FCC Class A, CE, VCCI

Safety Approvals
  • UL, CUL

Weight

  • 7.72 lbs (3.5 Kg)

Warranty Information

Warranty

  • 1-Year Limited*

Ordering Information

DPS-600

  • Redundant Power Supply Unit, 500 Watt RPSU

* 1-Year Limited Warranty available only in the USA and Canada.