+/-2% (measured output load from +/-10% rated load)
Load Regulation
+/-5% (measured output load from 20% to 100% rated load)
Output Ripple & Noise
120mV (measured bandwidth oscilloscope and terminated each output with 100uF capacitor and 0.1uF ceramic in parallel)
Total Output Power
60 watts
Efficiency
75% min. @ max. load and 115VAC input
Hold Up Time
16mS min. at max. load and 115VAC input, @ 60Hz output drop down to 95% output voltage
Over Current Protection
Power supply protected against overload and short circuit applied to any one terminal - auto restart * *Output can be shorted permanently with damage
Over Voltage Protection
13.5V to 17V
AC Power Good (pwr-good)
Signal Required
+3.3V * *(1) Minimum high voltage is 2.0V with a maximum load current of 5.0mA (2) Maximum high voltage is 3.4V (3) Minimum low voltage is 0.0V (4) Power good signal must go low within 0.5ms before 12V output drops out of below 10.0V (5) Power good signal must go high within 2.5 seconds of application of power to the system
LED Status
On: RPS good
Off: RPS failed
Dimensions
127mm (L) x 76mm (W) x 37mm (H)
Weight
0.83 kg
Operating Altitude
3,000 m (10,000 feet) max.
Storage Altitude
12,000 m (40,000 feet) max.
Operating Temperature
0° to 50° C
Storage Temperature
-20° to 80° C
Safety Standards
-CSA
EMI
FCC Class B
EN55022 (CISPR22) Class B
HI-POT Test
Input to secondary: 3000VAC for 1 minute, 10mA
Input to P.E.: 1500VAC for 1 minute, 10mA
Insulation Resistance
Input to secondary: >20Mohm 500VDC
Reliability (MTBF)
50K Hrs Min. at 25 degrees C 240VAC (max load)
Shock & Vibration
10-55Hz, amplitude 2G over entire frequency range. Sweep minute for X, Y and Z axis each 20 cycles.